RF measurements of a C-band cavity beam position monitor

Get Citation
CHU Jian-Hua, TONG De-Chun and ZHAO Zhen-Tang. RF measurements of a C-band cavity beam position monitor[J]. Chinese Physics C, 2008, 32(5): 385-388. doi: 10.1088/1674-1137/32/5/012
CHU Jian-Hua, TONG De-Chun and ZHAO Zhen-Tang. RF measurements of a C-band cavity beam position monitor[J]. Chinese Physics C, 2008, 32(5): 385-388.  doi: 10.1088/1674-1137/32/5/012 shu
Milestone
Received: 2007-07-19
Revised: 2007-09-03
Article Metric

Article Views(2631)
PDF Downloads(704)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

RF measurements of a C-band cavity beam position monitor

    Corresponding author: ZHAO Zhen-Tang,

Abstract: 

RF cold test of a novel C-band cavity beam position monitor (PBM) to be used in the SDUV-FEL Test Facility is described. The test results are presented and some characteristics discussed. The main parameters obtained are in reasonable agreement with the analytical estimations. Effective suppression of the common mode has been demonstrated. The position sensitivity over the test region of ±0.5 mm is about -21.58 dB/10 μm for the TM110 mode and is linear in the central region of the BPM cavity.