Beam hardening correction for a cone-beam CT system and its effect on spatial resolution

Get Citation
ZHAO Wei, FU Guo-Tao, SUN Cui-Li, WANG Yan-Fang, WEI Cun-Feng, CAO Da-Quan, QUE Jie-Min, TANG Xiao, SHI Rong-Jian, WEI Long and YU Zhong-Qiang. Beam hardening correction for a cone-beam CT system and its effect on spatial resolution[J]. Chinese Physics C, 2011, 35(10): 978-985. doi: 10.1088/1674-1137/35/10/018
ZHAO Wei, FU Guo-Tao, SUN Cui-Li, WANG Yan-Fang, WEI Cun-Feng, CAO Da-Quan, QUE Jie-Min, TANG Xiao, SHI Rong-Jian, WEI Long and YU Zhong-Qiang. Beam hardening correction for a cone-beam CT system and its effect on spatial resolution[J]. Chinese Physics C, 2011, 35(10): 978-985.  doi: 10.1088/1674-1137/35/10/018 shu
Milestone
Received: 2011-01-24
Revised: 2011-04-18
Article Metric

Article Views(2445)
PDF Downloads(498)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Beam hardening correction for a cone-beam CT system and its effect on spatial resolution

Abstract: In this paper, we present a beam hardening correction (BHC) method in three-dimension space for a cone-beam computed tomography (CBCT) system in a mono-material case and investigate its effect on the spatial resolution. Due to the polychromatic character of the X-ray spectrum used, cupping and streak artifacts called beam hardening artifacts arise in the reconstructed CT images, causing reduced image quality. In addition, enhanced edges are introduced in the reconstructed CT images because of the beam hardening effect. The spatial resolution of the CBCT system is calculated from the edge response function (ERF) on different planes in space. Thus, in the CT images with beam hardening artifacts, enhanced ERFs will be extracted to calculate the modulation transfer function (MTF), obtaining a better spatial resolution that deviates from the real value. Reasonable spatial resolution can be obtained after reducing the artifacts. The 10% MTF value and the full width at half maximum (FWHM) of the point spread function with and without BHC are presented.