×
近期发现有不法分子冒充我刊与作者联系,借此进行欺诈等不法行为,请广大作者加以鉴别,如遇诈骗行为,请第一时间与我刊编辑部联系确认(《中国物理C》(英文)编辑部电话:010-88235947,010-88236950),并作报警处理。
本刊再次郑重声明:
(1)本刊官方网址为cpc.ihep.ac.cn和https://iopscience.iop.org/journal/1674-1137
(2)本刊采编系统作者中心是投稿的唯一路径,该系统为ScholarOne远程稿件采编系统,仅在本刊投稿网网址(https://mc03.manuscriptcentral.com/cpc)设有登录入口。本刊不接受其他方式的投稿,如打印稿投稿、E-mail信箱投稿等,若以此种方式接收投稿均为假冒。
(3)所有投稿均需经过严格的同行评议、编辑加工后方可发表,本刊不存在所谓的“编辑部内部征稿”。如果有人以“编辑部内部人员”名义帮助作者发稿,并收取发表费用,均为假冒。
                  
《中国物理C》(英文)编辑部
2024年10月30日

Beam test of a one-dimensional position sensitive chamber on synchrotron radiation

Get Citation
LIU Mei, DAI Hong-Liang, QI Hui-Rong, ZHUANG Bao-An, ZHANG Jian, LIU Rong-Guang, ZHU Qi-Ming, OUYANG Qun, CHEN Yuan-Bo, JIANG Xiao-Shan, WANG Ya-Jie, LIU Peng and CHANG Guang-Cai. Beam test of a one-dimensional position sensitive chamber on synchrotron radiation[J]. Chinese Physics C, 2013, 37(10): 108001. doi: 10.1088/1674-1137/37/10/108001
LIU Mei, DAI Hong-Liang, QI Hui-Rong, ZHUANG Bao-An, ZHANG Jian, LIU Rong-Guang, ZHU Qi-Ming, OUYANG Qun, CHEN Yuan-Bo, JIANG Xiao-Shan, WANG Ya-Jie, LIU Peng and CHANG Guang-Cai. Beam test of a one-dimensional position sensitive chamber on synchrotron radiation[J]. Chinese Physics C, 2013, 37(10): 108001.  doi: 10.1088/1674-1137/37/10/108001 shu
Milestone
Received: 2012-11-19
Revised: 2012-12-21
Article Metric

Article Views(1876)
PDF Downloads(196)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Beam test of a one-dimensional position sensitive chamber on synchrotron radiation

    Corresponding author: LIU Mei,
    Corresponding author: QI Hui-Rong,

Abstract: A one-dimensional single-wire chamber was developed to provide high position resolution for powder diffraction experiments with synchrotron radiation. A diffraction test using the sample of SiO2 has been accomplished at 1W2B laboratory of Beijing Synchrotron Radiation Source. The data of the beam test were analyzed and some diffraction angles were obtained. The experimental results were in good agreement with standard data from ICDD powder diffraction file. The precision of diffraction angles was 1% to 4.7%. Most of the relative errors between measured values of diffraction angles and existing data were less than 1%. As for the detector, the best position resolution in the test was 138 μm (σ value) with an X-ray tube. Finally, discussions of the results were given. The major factor that affected the precision of measurement was deviation from the flat structure of the detector. The effect was analyzed and the conclusion was reached that it would be the optimal measurement scheme when the distance between the powder sample and detector was from 400 mm to 600 mm.

    HTML

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return