First neutron spectrometry measurement at the HL-2A Tokamak

Get Citation
YUAN Xi, ZHANG Xing, XIE Xu-Fei, CHEN Zhong-Jing, PENG Xing-Yu, FAN Tie-Shuan, CHEN Jin-Xiang, LI Xiang-Qing, YUAN Guo-Liang, YANG Qing-Wei and YANG Jin-Wei. First neutron spectrometry measurement at the HL-2A Tokamak[J]. Chinese Physics C, 2013, 37(12): 126001. doi: 10.1088/1674-1137/37/12/126001
YUAN Xi, ZHANG Xing, XIE Xu-Fei, CHEN Zhong-Jing, PENG Xing-Yu, FAN Tie-Shuan, CHEN Jin-Xiang, LI Xiang-Qing, YUAN Guo-Liang, YANG Qing-Wei and YANG Jin-Wei. First neutron spectrometry measurement at the HL-2A Tokamak[J]. Chinese Physics C, 2013, 37(12): 126001.  doi: 10.1088/1674-1137/37/12/126001 shu
Milestone
Received: 2013-04-11
Revised: 1900-01-01
Article Metric

Article Views(1690)
PDF Downloads(307)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

First neutron spectrometry measurement at the HL-2A Tokamak

    Corresponding author: FAN Tie-Shuan,

Abstract: A compact neutron spectrometer based on the liquid scintillator is presented for neutron energy spectrum measurements at the HL-2A Tokamak. The spectrometer was well characterized and a fast digital pulse shape discrimination software was developed using the charge comparison method. A digitizer data acquisition system with a maximum frequency of 1 MHz can work under an environment with a high count rate at HL-2A Tokamak. Specific radiation and magnetic shielding for the spectrometer were designed for the neutron spectrum measurement at the HL-2A Tokamak. For pulse height spectrum analysis, dedicated numerical simulation utilizing NUBEAM combined with GENESIS was performed to obtain the neutron energy spectrum. Subsequently, the transportation process from the plasma to the detector was evaluated with Monte Carlo calculations. The distorted neutron energy spectrum was folded with the response matrix of the liquid scintillation spectrometer, and good consistency was found between the simulated and measured pulse height spectra. This neutron spectrometer based on a digital acquisition system could be well adopted for the investigation of the auxiliary heating behavior and the fast-ion related phenomenon on different tokamak devices.

    HTML

Reference (1)

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return