×
近期发现有不法分子冒充我刊与作者联系,借此进行欺诈等不法行为,请广大作者加以鉴别,如遇诈骗行为,请第一时间与我刊编辑部联系确认(《中国物理C》(英文)编辑部电话:010-88235947,010-88236950),并作报警处理。
本刊再次郑重声明:
(1)本刊官方网址为cpc.ihep.ac.cn和https://iopscience.iop.org/journal/1674-1137
(2)本刊采编系统作者中心是投稿的唯一路径,该系统为ScholarOne远程稿件采编系统,仅在本刊投稿网网址(https://mc03.manuscriptcentral.com/cpc)设有登录入口。本刊不接受其他方式的投稿,如打印稿投稿、E-mail信箱投稿等,若以此种方式接收投稿均为假冒。
(3)所有投稿均需经过严格的同行评议、编辑加工后方可发表,本刊不存在所谓的“编辑部内部征稿”。如果有人以“编辑部内部人员”名义帮助作者发稿,并收取发表费用,均为假冒。
                  
《中国物理C》(英文)编辑部
2024年10月30日

Recalculation of the HIRFL-SSC injection and extraction system

Get Citation
YE Feng. Recalculation of the HIRFL-SSC injection and extraction system[J]. Chinese Physics C, 2013, 37(4): 047001. doi: 10.1088/1674-1137/37/4/047001
YE Feng. Recalculation of the HIRFL-SSC injection and extraction system[J]. Chinese Physics C, 2013, 37(4): 047001.  doi: 10.1088/1674-1137/37/4/047001 shu
Milestone
Received: 2011-10-10
Revised: 1900-01-01
Article Metric

Article Views(1518)
PDF Downloads(359)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Recalculation of the HIRFL-SSC injection and extraction system

    Corresponding author: YE Feng,
  • Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000, China

Abstract: In order to further improve beam transmission efficiency at the SSC, the beam center trajectory and injection and extraction system are recalculated based on the program group used in the final design of the GANIL accelerator, with some necessary changes and the addition of some auxiliary programs. The two different types of injection and extraction elements (the bending magnet and the inductive septum) are distinguished, and their interaction with the ambient field is considered. More focus is placed on considering the differences in the magnet field inhomogeneity of the ambient field in the located area of the inductive septum where the ends are situated in the ambient field (between the main magnet poles). Thus the gradient magnetic field problem of the inductive septum is solved perfectly. As well as preparing the necessary auxiliary programs and taking the structural integration of the SSC magnetic field maps, the measured magnet field correction is completed. Therefore, the trajectory and a variety of injection and extraction system parameters are obtained. According to the recalculation results, the SSC beam transmission efficiency will be enhanced significantly.

    HTML

Reference (1)

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return