×
近期发现有不法分子冒充我刊与作者联系,借此进行欺诈等不法行为,请广大作者加以鉴别,如遇诈骗行为,请第一时间与我刊编辑部联系确认(《中国物理C》(英文)编辑部电话:010-88235947,010-88236950),并作报警处理。
本刊再次郑重声明:
(1)本刊官方网址为cpc.ihep.ac.cn和https://iopscience.iop.org/journal/1674-1137
(2)本刊采编系统作者中心是投稿的唯一路径,该系统为ScholarOne远程稿件采编系统,仅在本刊投稿网网址(https://mc03.manuscriptcentral.com/cpc)设有登录入口。本刊不接受其他方式的投稿,如打印稿投稿、E-mail信箱投稿等,若以此种方式接收投稿均为假冒。
(3)所有投稿均需经过严格的同行评议、编辑加工后方可发表,本刊不存在所谓的“编辑部内部征稿”。如果有人以“编辑部内部人员”名义帮助作者发稿,并收取发表费用,均为假冒。
                  
《中国物理C》(英文)编辑部
2024年10月30日

A user-friendly nano-CT image alignment and 3D reconstruction platform based on LabVIEW

Get Citation
WANG Sheng-Hao, ZHANG Kai, WANG Zhi-Li, GAO Kun, WU Zhao, ZHU Pei-Ping and WU Zi-Yu. A user-friendly nano-CT image alignment and 3D reconstruction platform based on LabVIEW[J]. Chinese Physics C, 2015, 39(1): 018001. doi: 10.1088/1674-1137/39/1/018001
WANG Sheng-Hao, ZHANG Kai, WANG Zhi-Li, GAO Kun, WU Zhao, ZHU Pei-Ping and WU Zi-Yu. A user-friendly nano-CT image alignment and 3D reconstruction platform based on LabVIEW[J]. Chinese Physics C, 2015, 39(1): 018001.  doi: 10.1088/1674-1137/39/1/018001 shu
Milestone
Received: 2014-02-17
Revised: 2014-05-27
Article Metric

Article Views(2221)
PDF Downloads(272)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

A user-friendly nano-CT image alignment and 3D reconstruction platform based on LabVIEW

    Corresponding author: ZHANG Kai,
    Corresponding author: WU Zi-Yu,

Abstract: X-ray computed tomography at the nanometer scale (nano-CT) offers a wide range of applications in scientific and industrial areas. Here we describe a reliable, user-friendly, and fast software package based on LabVIEW that may allow us to perform all procedures after the acquisition of raw projection images in order to obtain the inner structure of the investigated sample. A suitable image alignment process to address misalignment problems among image series due to mechanical manufacturing errors, thermal expansion, and other external factors has been considered, together with a novel fast parallel beam 3D reconstruction procedure that was developed ad hoc to perform the tomographic reconstruction. We have obtained remarkably improved reconstruction results at the Beijing Synchrotron Radiation Facility after the image calibration, the fundamental role of this image alignment procedure was confirmed, which minimizes the unwanted blurs and additional streaking artifacts that are always present in reconstructed slices. Moreover, this nano-CT image alignment and its associated 3D reconstruction procedure are fully based on LabVIEW routines, significantly reducing the data post-processing cycle, thus making the activity of the users faster and easier during experimental runs.

    HTML

Reference (1)

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return