×
近期发现有不法分子冒充我刊与作者联系,借此进行欺诈等不法行为,请广大作者加以鉴别,如遇诈骗行为,请第一时间与我刊编辑部联系确认(《中国物理C》(英文)编辑部电话:010-88235947,010-88236950),并作报警处理。
本刊再次郑重声明:
(1)本刊官方网址为cpc.ihep.ac.cn和https://iopscience.iop.org/journal/1674-1137
(2)本刊采编系统作者中心是投稿的唯一路径,该系统为ScholarOne远程稿件采编系统,仅在本刊投稿网网址(https://mc03.manuscriptcentral.com/cpc)设有登录入口。本刊不接受其他方式的投稿,如打印稿投稿、E-mail信箱投稿等,若以此种方式接收投稿均为假冒。
(3)所有投稿均需经过严格的同行评议、编辑加工后方可发表,本刊不存在所谓的“编辑部内部征稿”。如果有人以“编辑部内部人员”名义帮助作者发稿,并收取发表费用,均为假冒。
                  
《中国物理C》(英文)编辑部
2024年10月30日

Get Citation
HONG Dao-Jin, YU Bo-Xiang, LIU Hong-Bang, HE Xiao-Rong, AN Guang-Peng, CHEN Hai-Tao, CHEN Shi, HU Tao, LI Jia-Cai, LIU Qian, NIU Shun-Li, RUAN Xiang-Dong, XIE Yi-Gang, ZHANG Xuan and ZHENG Yang-Heng. p/π+ response of single layer THGEM detector in Ar+3% iC4H10[J]. Chinese Physics C, 2015, 39(9): 096002. doi: 10.1088/1674-1137/39/9/096002
HONG Dao-Jin, YU Bo-Xiang, LIU Hong-Bang, HE Xiao-Rong, AN Guang-Peng, CHEN Hai-Tao, CHEN Shi, HU Tao, LI Jia-Cai, LIU Qian, NIU Shun-Li, RUAN Xiang-Dong, XIE Yi-Gang, ZHANG Xuan and ZHENG Yang-Heng. p/π+ response of single layer THGEM detector in Ar+3% iC4H10[J]. Chinese Physics C, 2015, 39(9): 096002.  doi: 10.1088/1674-1137/39/9/096002 shu
Milestone
Received: 2014-11-25
Revised: 2015-04-14
Article Metric

Article Views(1963)
PDF Downloads(149)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

p/π+ response of single layer THGEM detector in Ar+3% iC4H10

    Corresponding author: LIU Hong-Bang,

Abstract: In this work, we study the response of a single layer Thick Gaseous Electron Multiplier (THGEM) detector to p/π+ at the E3 line of the Beijing Test Beam Facility. The THGEM detector drift gap used in this study is 4 mm, and the gain of the detector operated in Ar+3% iC4H10 is about 2000. p/π+ particles at momenta between 500 MeV/c and 1000 MeV/c are distinguished by a Time Of Flight system. Our results show that at the measured momenta, detection efficiencies for p are from 93% to 99%, and for π + in the range of 82%-88%. Meanwhile, simple Geant4 simulations also have been done, and are consistent with the amplitude spectra of the beam test results. We preliminarily study the feasibility of the THGEM detector as a sampling element for a Digital Hadronic Calorimeter (DHCAL), which may provide support for the possible application of a THGEM detector in the Circular Electron Positron Collider (CEPC) HCAL.

    HTML

Reference (1)

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return