An ultrafast front-end ASIC for APD array detectors in X-ray time-resolved experiments

Get Citation
Yang-Fan Zhou, Qiu-Ju Li, Peng Liu, Lei Fan, Wei Xu, Ye Tao and Zhen-Jie Li. An ultrafast front-end ASIC for APD array detectors in X-ray time-resolved experiments[J]. Chinese Physics C, 2017, 41(6): 066101. doi: 10.1088/1674-1137/41/6/066101
Yang-Fan Zhou, Qiu-Ju Li, Peng Liu, Lei Fan, Wei Xu, Ye Tao and Zhen-Jie Li. An ultrafast front-end ASIC for APD array detectors in X-ray time-resolved experiments[J]. Chinese Physics C, 2017, 41(6): 066101.  doi: 10.1088/1674-1137/41/6/066101 shu
Milestone
Received: 2017-02-04
Fund

    Supported by the National Natural Science Foundation of China (11605227), High Energy Photon Source-Test Facility Project, and the State Key Laboratory of Particle Detection and Electronics. This research used resources of the BSRF.}

Article Metric

Article Views(1271)
PDF Downloads(46)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

An ultrafast front-end ASIC for APD array detectors in X-ray time-resolved experiments

    Corresponding author: Yang-Fan Zhou,
    Corresponding author: Zhen-Jie Li,
  • 1.  Beijing Synchrotron Radiation Facility, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, China
  • 2.  State Key Laboratory of Particle Detection and Electronics, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, China
Fund Project:  Supported by the National Natural Science Foundation of China (11605227), High Energy Photon Source-Test Facility Project, and the State Key Laboratory of Particle Detection and Electronics. This research used resources of the BSRF.}

Abstract: An ultrafast front-end ASIC chip has been developed for APD array detectors in X-ray time-resolved experiments. The chip has five channels: four complete channels and one test channel with an analog output. Each complete channel consists of a preamplifier, a voltage discriminator and an open-drain output driver. A prototype chip has been designed and fabricated using 0.13 μm CMOS technology with a chip size of 1.3 mm×1.9 mm. The electrical characterizations of the circuit demonstrate a very good intrinsic time resolution (rms) on the output pulse leading edge, with the test result better than 30 ps for high input signal charges (> 75 fC) and better than 100 ps for low input signal charges (30-75 fC), while keeping a low power consumption of 5 mW per complete channel.