×
近期发现有不法分子冒充我刊与作者联系,借此进行欺诈等不法行为,请广大作者加以鉴别,如遇诈骗行为,请第一时间与我刊编辑部联系确认(《中国物理C》(英文)编辑部电话:010-88235947,010-88236950),并作报警处理。
本刊再次郑重声明:
(1)本刊官方网址为cpc.ihep.ac.cn和https://iopscience.iop.org/journal/1674-1137
(2)本刊采编系统作者中心是投稿的唯一路径,该系统为ScholarOne远程稿件采编系统,仅在本刊投稿网网址(https://mc03.manuscriptcentral.com/cpc)设有登录入口。本刊不接受其他方式的投稿,如打印稿投稿、E-mail信箱投稿等,若以此种方式接收投稿均为假冒。
(3)所有投稿均需经过严格的同行评议、编辑加工后方可发表,本刊不存在所谓的“编辑部内部征稿”。如果有人以“编辑部内部人员”名义帮助作者发稿,并收取发表费用,均为假冒。
                  
《中国物理C》(英文)编辑部
2024年10月30日

Spatial Distribution of Elements in the Brain of Rats Measured by Synchrotron Radiation X-ray Fluoresence

Get Citation
FENG Liu-Xing, XIAO Hai-Qing, HE Xiao, ZHANG Zhi-Yong, LIU Nian-Qing, ZHAO Yu-Liang and HUANG Yu-Ying. Spatial Distribution of Elements in the Brain of Rats Measured by Synchrotron Radiation X-ray Fluoresence[J]. Chinese Physics C, 2005, 29(10): 1012-1016.
FENG Liu-Xing, XIAO Hai-Qing, HE Xiao, ZHANG Zhi-Yong, LIU Nian-Qing, ZHAO Yu-Liang and HUANG Yu-Ying. Spatial Distribution of Elements in the Brain of Rats Measured by Synchrotron Radiation X-ray Fluoresence[J]. Chinese Physics C, 2005, 29(10): 1012-1016. shu
Milestone
Received: 2005-02-17
Revised: 1900-01-01
Article Metric

Article Views(3392)
PDF Downloads(677)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Spatial Distribution of Elements in the Brain of Rats Measured by Synchrotron Radiation X-ray Fluoresence

    Corresponding author: ZHANG Zhi-Yong,
  • Key Laboratory of Nuclear Analytical Techniques,Institute of High Energy Physics,CAS,Beijing 100049,China2 Graduate School of the Chinese Academy of Sciences,Beijing 100049,China3 Beijing Synchrotron Radiation Facility,Institute of High Energy Physics,CAS,Beijing 100049,China

Abstract: Spatial(two-dimensional)distributions of inorganic elements such as chlorine,potassium, calcium,iron,copper,and zinc in the brain slices of Wistar rats were measured by synchrotron radiation X-ray fluorescence (SRXRF) analysis. Differences in two-dimensional distribution of these elements were observed. Chlorine, calcium, and zinc were primarily concentrated in hippocampus, while the potassium concentration was relatively higher in both cerebral cortex and hippocampus. However,the distribution of copper was comparatively ruleless in the three brain regions. The cluster analysis of the elemental results shows that the spatial distribution of chlorine was correlated well with the distribution of potassium.Since SRXRF is possible to obtain a pictorial representation of the elemental concentrations in tissue sections of brain, this nuclear method may be useful to evaluate the ionic changes in injured brain tissues in relation to histological observations.

    HTML

Reference (1)

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return