A new type of Time-Of-Propagation (TOP) Cherenkov detector for particle identification
- Received Date: 2008-07-17
- Accepted Date: 1900-01-01
- Available Online: 2008-01-03
Abstract: A new type of particle identification (PID) detector based on measurements of 1-D Time-Of-Propagation (TOP) and 1-D space information is described. Geant4 toolkit is used to simulate the propagation of Cherenkov photon in thin quartz bar radiator. Contributions to the timing uncertainty are discussed. The π/K separability (S0) is defined and its dependence on the particle momentum, incident angle and propagation length are studied, respectively.