×
近期发现有不法分子冒充我刊与作者联系,借此进行欺诈等不法行为,请广大作者加以鉴别,如遇诈骗行为,请第一时间与我刊编辑部联系确认(《中国物理C》(英文)编辑部电话:010-88235947,010-88236950),并作报警处理。
本刊再次郑重声明:
(1)本刊官方网址为cpc.ihep.ac.cn和https://iopscience.iop.org/journal/1674-1137
(2)本刊采编系统作者中心是投稿的唯一路径,该系统为ScholarOne远程稿件采编系统,仅在本刊投稿网网址(https://mc03.manuscriptcentral.com/cpc)设有登录入口。本刊不接受其他方式的投稿,如打印稿投稿、E-mail信箱投稿等,若以此种方式接收投稿均为假冒。
(3)所有投稿均需经过严格的同行评议、编辑加工后方可发表,本刊不存在所谓的“编辑部内部征稿”。如果有人以“编辑部内部人员”名义帮助作者发稿,并收取发表费用,均为假冒。
                  
《中国物理C》(英文)编辑部
2024年10月30日

Developments of a 2D position sensitiveneutron detector

Get Citation
TIAN Li-Chao, TANG Bin, WANG Xiao-Hu, LIU Rong-Guang, ZHANG Jian, CHEN Yuan-Bo, SUN Zhi-Jia, XU Hong, YANG Gui-An and ZHANG Qiang. Developments of a 2D position sensitiveneutron detector[J]. Chinese Physics C, 2012, 36(6): 525-530. doi: 10.1088/1674-1137/36/6/008
TIAN Li-Chao, TANG Bin, WANG Xiao-Hu, LIU Rong-Guang, ZHANG Jian, CHEN Yuan-Bo, SUN Zhi-Jia, XU Hong, YANG Gui-An and ZHANG Qiang. Developments of a 2D position sensitiveneutron detector[J]. Chinese Physics C, 2012, 36(6): 525-530.  doi: 10.1088/1674-1137/36/6/008 shu
Milestone
Received: 2011-08-29
Revised: 2011-10-18
Article Metric

Article Views(2463)
PDF Downloads(466)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Developments of a 2D position sensitiveneutron detector

    Corresponding author: TIAN Li-Chao,
    Corresponding author: SUN Zhi-Jia,

Abstract: China Spallation Neutron Source (CSNS), one project of the 12th Five-Year-Plan scheme of China, is under construction in Guangdong province. Three neutron spectrometers will be installed during the first phase of the project, and two-dimensional position sensitive thermal neutron detectors are required. Before the construction of the neutron detectors, a prototype of a two-dimensional 200 mm×200 mm Multi-wire Proportional Chamber (MWPC) with Ar/CO2 (90/10) flowing gas has been constructed. In 2009, the prototype was tested with the 55Fe X-ray using part of the electronics, and performed well.
Following the test in 2009, the neutron detector was constructed with the complete electronics and filled with the 6 atm. 3He+2.5 atm. C3H8 gas mixture in 2010. The neutron detector has been primarily tested with an Am-Be source. In this paper, new developments of the neutron detector including the design of the high pressure chamber, the optimization of the gas purifying system and the gas filling process will be reported. The results and discussion are also presented in this paper.

    HTML

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return