Abstract:
The photoelectron spectroscopy beamline at National Synchrotron Radiation Laboratory (NSRL) is equipped with a spherical grating monochromator with the included angle of 174°. Three gratings with line density of 200,700 and 1200 lines/mm are used to cover the energy region from 60 eV to 1000 eV. After several years' operation,the spectral resolution and flux throughput were deteriorated,and realignment was necessary to improve the performance. First,the wavelength scanning mechanism,the optical components position and the exit slit guide direction are aligned according to the design value. Second,the gratings are checked by Atomic Force Microscopy (AFM) and then the gas absorption spectrum is measured to optimize the focusing condition of the monochromator. The spectral resolving power E/ΔE is recovered to the designed value of 1000@244 eV. The flux at the end station for the 200 lines/mm grating is about 1010 photons/sec/200 mA,which is in accordance with the design. The photon flux for the 700 lines/mm grating is about 5×108 photons/sec/200mA,which is lower than expected. This poor flux throughput may be caused by carbon contamination on the optical components. The 1200 lines/mm grating has roughness much higher than expected so the diffraction efficiency is too low to detect any signal. A new grating would be ordered. After the alignment,the beamline has significant performance improvements in both the resolving power and the flux throughput for 200 and 700 lines/mm gratings and is provided to users.
-
-
References
[1]
|
Wagner C D et al. Handbook of X-ray Photoelectron Spectroscopy,{Perkin-Eimer Corporation Physical Electronics Division USA Minnesota,1979[2] CHEN C T. Nucl. Instrum. Methods A,1987,256: 595-604[3] CHEN C T,Sette F. Rev. Sci. Instrum.,1989,60: 1616-1621[4] Petersen H,Jung C,Hellwig C et al. Rev. Sci. Instrum.,1995,66: 1-14[5] XU P S,WANG Q P,LU X J et al. Rev. Sci. Instrum.,1995,66: 1830-1832[6] Ehrhardt J C,Davis S P. J. Opt. Soc. Am.,1971,61: 1342-1349[7] Patanen M,Aksela S,Urpelainen S et al. J. Electron Spectrosc. Relat. Phenom.,2011,183: 59-63[8] WANG Q P,ZHANG Y W. Rev. Sci. Instrum.,1995,66: 2284-2286[9] ZHOU H J,WANG Q P,ZHENG J J et al. Opt. Precision Eng. 2006,14: 351-355[10] Domke M,Mandel T,Puschmann A et al. Rev. Sci. Instrum.,1992,63: 80-89 |
-
[1] |
Y. P. Wang
, Y. K. Wang
, P. W. Zhao
. Tilted-axis-cranking covariant density functional theory for the high-spin spectroscopy in 69Ga. Chinese Physics C,
2026, 50(2): 1-5.
doi: 10.1088/1674-1137/ae07b8
|
[2] |
WANG Ji-Ke
, MAO Ze-Pu
, BIAN Jian-Ming
, CAO Guo-Fu
, CAO Xue-Xiang
, CHEN Shen-Jian
, DENG Zi-Yan
, FU Cheng-Dong
, GAO Yuan-Ning
, HE Kang-Lin
, HE Miao
, HUA Chun-Fei
, HUANG Bin
, HUANG Xing-Tao
, JI Xiao-Bin
, LI Fei
, LI Hai-Bo
, LI Wei-Dong
, LIANG Yu-Tie
, LIU Chun-Xiu
, LIU Huai-Min
, LIU Suo
, LIU Ying-Jie
, MA Qiu-Mei
, MA Xiang
, MAO Ya-Jun
, MO Xiao-Hu
, PAN Ming-Hua
, PANG Cai-Ying
, PING Rong-Gang
, QIN Ya-Hong
, QIU Jin-Fa
, SUN Sheng-Sen
, SUN Yong-Zhao
, WANG Liang-Liang
, WEN Shuo-Pin
,
,
,
,
,
,
. Software alignment of the BESⅢ main drift chamber using the Kalman Filter method. Chinese Physics C,
2009, 33(3): 210-216.
doi: 10.1088/1674-1137/33/3/010
|
[3] |
FAN Ping
, YUAN Da-Qing
, ZUO Yi
, ZHENG Yong-Nan
, ZHOU Dong-Mei
, WU Xiao-Guang
, LI Guang-Sheng
, ZHU Li-Hua
, XU Guo-Ji
, FAN Qi-Wen
, ZHANG Xi-Zhen
, ZHU Sheng-Yun
. Proton alignment in 82Sr investigated by g-factor measurements. Chinese Physics C,
2009, 33(S1): 206-208.
doi: 10.1088/1674-1137/33/S1/066
|
-
Access
-
-