Beam experiments with a non-intercepting beam induced fluorescence profile monitor for the ADS LINAC

Get Citation
XIE Hong-Ming, WU Jun-Xia, ZHANG Yong, ZHU Guang-Yu, XIA Jia-Wen and YE Min-You. Beam experiments with a non-intercepting beam induced fluorescence profile monitor for the ADS LINAC[J]. Chinese Physics C, 2015, 39(11): 117004. doi: 10.1088/1674-1137/39/11/117004
XIE Hong-Ming, WU Jun-Xia, ZHANG Yong, ZHU Guang-Yu, XIA Jia-Wen and YE Min-You. Beam experiments with a non-intercepting beam induced fluorescence profile monitor for the ADS LINAC[J]. Chinese Physics C, 2015, 39(11): 117004.  doi: 10.1088/1674-1137/39/11/117004 shu
Milestone
Received: 2015-01-16
Revised: 2015-05-25
Article Metric

Article Views(1356)
PDF Downloads(43)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Beam experiments with a non-intercepting beam induced fluorescence profile monitor for the ADS LINAC

Abstract: An accelerator-driven subcritical system (ADS) project was launched in China in 2011, aiming to design and build an ADS demonstration facility with the capability of more than 1000 MW thermal power. The driver linac is defined to be a 10 mA current of high energy protons at 1.5 GeV in continuous wave operation mode. To meet the extremely high power and intense beam accelerator requirements, non-interceptive monitors for the beam transverse profile are required for this proton linac. Taking advantage of the residual gas as active material, the Beam Induced Fluorescence (BIF) monitor exploits gas-excited fluorescence in the visible spectrum region for transverse profile measurements. The advantages of this non-intercepting method are that nothing is installed in the vacuum pipe, component design is compact and there is no need for expensive signal processing electronics. Beam experiments have been performed under constant beam conditions. The helium spectrum has been verified with different optical filters, showing that a proper optical band-pass filter covering 400-500 nm is necessary for fluorescence experiments with helium. By changing gas pressure, it is shown that gas pressure is proportional to the signal amplitude but has no influence on detected profile width. Finally, a comparison experiment between the BIF monitor and a wire scanner shows that the detected profile width results of both methods agree well.