D0-D0 mixing sensitivity estimation at Belle Ⅱ in wrong-sign decays D0→K+π-π0 via time-dependent amplitude analysis

Get Citation
Long-Ke Li, Ye-Qi Chen, Wen-Biao Yan and Zi-Ping Zhang. D0-D0 mixing sensitivity estimation at Belle Ⅱ in wrong-sign decays D0→K+π-π0 via time-dependent amplitude analysis[J]. Chinese Physics C, 2017, 41(2): 023001. doi: 10.1088/1674-1137/41/2/023001
Long-Ke Li, Ye-Qi Chen, Wen-Biao Yan and Zi-Ping Zhang. D0-D0 mixing sensitivity estimation at Belle Ⅱ in wrong-sign decays D0→K+π-π0 via time-dependent amplitude analysis[J]. Chinese Physics C, 2017, 41(2): 023001.  doi: 10.1088/1674-1137/41/2/023001 shu
Milestone
Received: 2016-09-21
Revised: 2016-10-14
Fund

    Supported by National Natural Science Foundation of China (11475164, 11475169, 11675166)

Article Metric

Article Views(1503)
PDF Downloads(58)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

D0-D0 mixing sensitivity estimation at Belle Ⅱ in wrong-sign decays D0→K+π-π0 via time-dependent amplitude analysis

    Corresponding author: Long-Ke Li,
    Corresponding author: Ye-Qi Chen,
    Corresponding author: Wen-Biao Yan,
    Corresponding author: Zi-Ping Zhang,
  • 1. University of Science and Technology of China, Hefei 230026, China
Fund Project:  Supported by National Natural Science Foundation of China (11475164, 11475169, 11675166)

Abstract: The sensitivity of the D0-D0 mixing parameters x and y is estimated in the wrong-sign decay D0→K+π-π0 by time-dependent amplitude analysis. The resolution of the D0 lifetime is essential in time-dependent Dalitz analyses. The Belle Ⅱ detector, which aims to collect a total integrated luminosity of 50 ab-1 of data, has σ=140 fs in Monte Carlo studies, a factor of two improvement over that of Belle and BaBar, so the produced Dalitz signal Monte Carlo samples are smeared with this resolution. Then a time-dependent Dalitz plot fitting is performed on these smeared samples, and the sensitivity of D0-D0 mixing parameters are σx=0.057% and σy=0.049%. These are about an order of magnitude improvement on current experimental results, without considering background effects.

    HTML

Reference (19)

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return