An optimal scheme for top quark mass measurement near the tt threshold at future e+e- colliders

Get Citation
Wei-Guo Chen, Xia Wan and You-Kai Wang. An optimal scheme for top quark mass measurement near the tt threshold at future e+e- colliders[J]. Chinese Physics C, 2018, 42(5): 053002. doi: 10.1088/1674-1137/42/5/053002
Wei-Guo Chen, Xia Wan and You-Kai Wang. An optimal scheme for top quark mass measurement near the tt threshold at future e+e- colliders[J]. Chinese Physics C, 2018, 42(5): 053002.  doi: 10.1088/1674-1137/42/5/053002 shu
Milestone
Received: 2018-01-05
Revised: 2018-03-04
Fund

    Supported by National Science Foundation of China (11405102) and the Fundamental Research Funds for the Central Universities of China (GK201603027, GK201803019)

Article Metric

Article Views(2765)
PDF Downloads(20)
Cited by(0)
Policy on re-use
To reuse of Open Access content published by CPC, for content published under the terms of the Creative Commons Attribution 3.0 license (“CC CY”), the users don’t need to request permission to copy, distribute and display the final published version of the article and to create derivative works, subject to appropriate attribution.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

An optimal scheme for top quark mass measurement near the tt threshold at future e+e- colliders

    Corresponding author: Wei-Guo Chen,
    Corresponding author: Xia Wan,
    Corresponding author: You-Kai Wang,
Fund Project:  Supported by National Science Foundation of China (11405102) and the Fundamental Research Funds for the Central Universities of China (GK201603027, GK201803019)

Abstract: A top quark mass measurement scheme near the tt production threshold in future e+e- colliders, e.g.the Circular Electron Positron Collider (CEPC), is simulated. A χ2 fitting method is adopted to determine the number of energy points to be taken and their locations. Our results show that the optimal energy point is located near the largest slope of the cross section v. beam energy plot, and the most efficient scheme is to concentrate all luminosity on this single energy point in the case of one-parameter top mass fitting. This suggests that the so-called data-driven method could be the best choice for future real experimental measurements. Conveniently, the top mass statistical uncertainty can also be calculated directly by the error matrix even without any sampling and fitting. The agreement of the above two optimization methods has been checked. Our conclusion is that by taking 50 fb-1 total effective integrated luminosity data, the statistical uncertainty of the top potential subtracted mass can be suppressed to about 7 MeV and the total uncertainty is about 30 MeV. This precision will help to identify the stability of the electroweak vacuum at the Planck scale.

    HTML

Reference (55)

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return