×
近期发现有不法分子冒充我刊与作者联系,借此进行欺诈等不法行为,请广大作者加以鉴别,如遇诈骗行为,请第一时间与我刊编辑部联系确认(《中国物理C》(英文)编辑部电话:010-88235947,010-88236950),并作报警处理。
本刊再次郑重声明:
(1)本刊官方网址为cpc.ihep.ac.cn和https://iopscience.iop.org/journal/1674-1137
(2)本刊采编系统作者中心是投稿的唯一路径,该系统为ScholarOne远程稿件采编系统,仅在本刊投稿网网址(https://mc03.manuscriptcentral.com/cpc)设有登录入口。本刊不接受其他方式的投稿,如打印稿投稿、E-mail信箱投稿等,若以此种方式接收投稿均为假冒。
(3)所有投稿均需经过严格的同行评议、编辑加工后方可发表,本刊不存在所谓的“编辑部内部征稿”。如果有人以“编辑部内部人员”名义帮助作者发稿,并收取发表费用,均为假冒。
                  
《中国物理C》(英文)编辑部
2024年10月30日

Study on the Analog Read-Out of the YBJ-ARGO RPC

Get Citation
YANG Qun-Yu, HE Hui-Hai, CHEN Xin, LIU Kun, LU Hong, MU Jun, SHEN Pei-Ruo, TAN You-Heng, WU Chao-Yong, ZHANG Hui-Min and ZHANG Yong. Study on the Analog Read-Out of the YBJ-ARGO RPC[J]. Chinese Physics C, 2004, 28(8): 866-869.
YANG Qun-Yu, HE Hui-Hai, CHEN Xin, LIU Kun, LU Hong, MU Jun, SHEN Pei-Ruo, TAN You-Heng, WU Chao-Yong, ZHANG Hui-Min and ZHANG Yong. Study on the Analog Read-Out of the YBJ-ARGO RPC[J]. Chinese Physics C, 2004, 28(8): 866-869. shu
Milestone
Received: 2004-01-14
Revised: 1900-01-01
Article Metric

Article Views(3401)
PDF Downloads(636)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Study on the Analog Read-Out of the YBJ-ARGO RPC

    Corresponding author: YANG Qun-Yu,
  • Department of Physics,Yunnan University,Kunming 650091,China2 Institute of High Energy Physics,CAS,Beijing 100039,China

Abstract: The YBJ ARGO experiment is presently in the mounting and debugging phase at the Yangbajing High Altitude Cosmic Ray Laboratory,Tibet,China.The YBJ ARGO EAS array is composed of bakelite RPCs which operate in the streamer mode.The digital read out,performed by means of read out strips,allows measuring the secondary particle number of small size air showers.To extend the dynamic range of the secondary particle number density up to 104/m2,thus to measure the component and spectrum of primary cosmic rays at the knee region,it is necessary to implement the analog read out of the RPC,which is achieved by encapsulating each RPC with two Big PADs.This paper reports on the primary analysis of the analog read out signal of the Big PAD under different gas mixtures,including the amplitude distribution and ratio of the single streamer signal.

    HTML

Reference (1)

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return