2-D Beam Profile Measurement Based on CT Algorithm with Rotating Multi-Wire Target

  • A new method for the 2–d low energy electron beam profile measurement is developed. based on the ct(computer tomography) algorithm, multi sets of data about the 1–d beam profile projections are attained by rotating the multi–wire target. then a 2–d beam profile is reconstructed from these projections with ct algorithm. the principle of this method is analyzed theoretically in detail and the initial facilities for the experiment with some results are presented.
  • 加载中
  • [1] . CHEN Si-Fu, XIA Lian-Sheng, ZHANG Lin-Wen et al. High PowerLaser and Particle Beams, 2003, 15( 3) : 279 -282(in Chinese)(陈思富,夏连胜,章林文等.强激光与粒子束,2003, IS(3):279-282)2. CHEN Si-Fu,Ding Bo-Nan, Xia Lian-Sheng et al. High Power Laser and Part icle Beams, 2002, 14( 2) : 317- 320(in Chinese)(陈思富,丁伯南,夏连胜等.强激光与粒子束,2002,14(2):317-320)3. Catravas P, LeemansW P,Esarey E et al. Proceedings of the 1999 Part icle Accelerator Conference. 1999. 3: 2111 - 21134. ZHUANG Tian-Ge. CT Principle and Algorithm. Shanghai: Shanghai Jiao Tong University Press, 1992. 31 -37, 63 (in Chinese)(庄天戈.CI'原理与算法.上海:上海交通大学出版社,1992,31-37. 63)5. SHI Jiu-De. Photoelectric Tube and Electron-Multiplier Phototube. Beijing: Nat ional Def ense Industry Press, 1981. 101 - 104(in Chinese)(史玖德.光电管与光电倍增管.北京:国防工业出版社,1981.101-104)6. Joy D C. A Database of Electron-Solid Int eract ions. USA: EM Facilit y,University of Tennessee, and Oak Ridge National Laboratory, 2001. 457. Pages L, Bertel E. Joffre H, Sklavenitis L. Atomic Data, 1972, 4(1) : 38
  • 加载中

Get Citation
YU Neng-Jie, TANG Chuan-Xiang, ZHENG Shu-Xin, LI Quan-Feng and GONG Ke. 2-D Beam Profile Measurement Based on CT Algorithm with Rotating Multi-Wire Target[J]. Chinese Physics C, 2005, 29(4): 408-412.
YU Neng-Jie, TANG Chuan-Xiang, ZHENG Shu-Xin, LI Quan-Feng and GONG Ke. 2-D Beam Profile Measurement Based on CT Algorithm with Rotating Multi-Wire Target[J]. Chinese Physics C, 2005, 29(4): 408-412. shu
Milestone
Received: 2004-07-13
Revised: 2004-09-07
Article Metric

Article Views(3764)
PDF Downloads(566)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

2-D Beam Profile Measurement Based on CT Algorithm with Rotating Multi-Wire Target

    Corresponding author: YU Neng-Jie,
  • Department of Engineering Physics,Tsinghua University,Beijing 100084,China

Abstract: A new method for the 2–d low energy electron beam profile measurement is developed. based on the ct(computer tomography) algorithm, multi sets of data about the 1–d beam profile projections are attained by rotating the multi–wire target. then a 2–d beam profile is reconstructed from these projections with ct algorithm. the principle of this method is analyzed theoretically in detail and the initial facilities for the experiment with some results are presented.

    HTML

Reference (1)

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return