Diagnosis of Individual Cell Frequencies in a Coupled Cavity Chain Without Introducing Objects Into the Cavity

  • In this paper, a new method that can diagnose the cell frequencies in a cavity without a perturbing probe is presented. The cell frequencies and couplings between cells arc estimated in terms of the measured passband performance. This method will simplify the tuning processes and make the tuning of a sealed cavity possible, It has been well checked with some numerical examples.
  • 加载中
  • [1] Habel E et al. Tuning of a Superconducting Acceleracting Cavity under Operating Conditions. CERN/ FF/RF81-5, 1981 [2] Nagle D E et al. The Review of Scientific Instruments, 1967, 38(11):1583-1588 [3] Yao Chongguo. Atomic Energy Science and Technology (in Chinese), 1986, 20(2):173-179(姚充国.原子能科学技术,1986, 20(2):173-179) [4] Xu Shiliang. Numerical Collection in C (in Chinese). Beijing: Tsinghua University Press, 1994. 235-239(徐士良.C常用算法程序集.北京:清华大学出版社,1994. 235-239) [5] Press W H et al. Numerical Recipes in C (Second Edition) (in Chinese).Beijing: Electronics Industry Press, 1995. 324-334(Press W H等,C语言数值算法程序大全(第二版).北京:电子工业出版社1995. 324-334)
  • 加载中

Get Citation
Ni Yi, Xiao Liling, Tong Dechun, Tian Bo, Jin Qingxiu and Huang Yuanzhong. Diagnosis of Individual Cell Frequencies in a Coupled Cavity Chain Without Introducing Objects Into the Cavity[J]. Chinese Physics C, 1998, 22(6): 570-575.
Ni Yi, Xiao Liling, Tong Dechun, Tian Bo, Jin Qingxiu and Huang Yuanzhong. Diagnosis of Individual Cell Frequencies in a Coupled Cavity Chain Without Introducing Objects Into the Cavity[J]. Chinese Physics C, 1998, 22(6): 570-575. shu
Milestone
Received: 1900-01-01
Revised: 1900-01-01
Article Metric

Article Views(2260)
PDF Downloads(551)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Diagnosis of Individual Cell Frequencies in a Coupled Cavity Chain Without Introducing Objects Into the Cavity

    Corresponding author: Ni Yi,
  • Department of Engineering Physics,Tsinghua University ,Beijing 100084

Abstract: In this paper, a new method that can diagnose the cell frequencies in a cavity without a perturbing probe is presented. The cell frequencies and couplings between cells arc estimated in terms of the measured passband performance. This method will simplify the tuning processes and make the tuning of a sealed cavity possible, It has been well checked with some numerical examples.

    HTML

Reference (1)

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return