A Si-PIN Detector Used for DPF Neutron Yield Measurement

  • In this paper, the structure and performance of the Si-PIN detector system are introduced. The neutron sensitivity of the proton recoil Si-PIN detector to 14 MeV neutron is analyzed. Meanwhile, the direct irradiation sensitivity is simulated by MCNP-4B program. Using the Si-PIN detector, the pulsed neutron yield from DPF device has been measured. The results are in accordance with the SDIN500 detector within 5% uncertainty.
  • 加载中
  • [1] .  HAN Min , LUO Chen-Mu et al . High Power Laser and Particle Beams ,1995 , 8 :461 —465 (in Chinese)(韩旻,罗承沐等, 强激光与粒子束,1995 ,8 :461 —465)2. LU Ming-Fang , HAN Min et al . Journal of Tsinghua University(Sci Tech) , 1996 , 36(5) :36 —41 (in Chinese)(吕铭方,韩旻等. 清华大学学报(自然科学版) ,1996 ,36 (5) :36 —41)3. OUYANG Xiao-Ping , LI Zhen-Fu , ZHANG Guo-Guang et al . Acta Physica Sinica , 2002 , 51 (7) :1502 —1505 (in chinese)(欧阳晓平,李真富,张国光等. 物理学报,2002 ,51 (7) :1502 —1505)4. ZHANG Guo-Guang. Scientific Technical Report of Northwest Institute of Nuclear Technology , 1999 , E1701 (in Chinese)(张国光. 西北核技术研究所科技报告. 1999 ,E1701)5. Briesmeister J F MCNP-A General Monte Carlo N-Particle Transport Code. 1997 , LA-12625-M6. HUANG Bao et al . Experiment and Research , 1982 , 3 :280 —294 (in Chinese)(黄豹等. 试验与研究,1982 ,3 :280 —294)
  • 加载中

Get Citation
ZHANG Guo-Guang, OUYANG Xiao-Ping, ZHANG Jian-Fu, LI Bei-Jing, SONG Ji-Wen and ZHANG Qian-Mei. A Si-PIN Detector Used for DPF Neutron Yield Measurement[J]. Chinese Physics C, 2004, 28(6): 634-636.
ZHANG Guo-Guang, OUYANG Xiao-Ping, ZHANG Jian-Fu, LI Bei-Jing, SONG Ji-Wen and ZHANG Qian-Mei. A Si-PIN Detector Used for DPF Neutron Yield Measurement[J]. Chinese Physics C, 2004, 28(6): 634-636. shu
Milestone
Received: 2003-11-17
Revised: 1900-01-01
Article Metric

Article Views(3624)
PDF Downloads(560)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

A Si-PIN Detector Used for DPF Neutron Yield Measurement

    Corresponding author: ZHANG Guo-Guang,
  • Northwest Institute of Nuclear Technology,Xi′an 710024,China

Abstract: In this paper, the structure and performance of the Si-PIN detector system are introduced. The neutron sensitivity of the proton recoil Si-PIN detector to 14 MeV neutron is analyzed. Meanwhile, the direct irradiation sensitivity is simulated by MCNP-4B program. Using the Si-PIN detector, the pulsed neutron yield from DPF device has been measured. The results are in accordance with the SDIN500 detector within 5% uncertainty.

    HTML

Reference (1)

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return