R&D Effort at NSCL with the Off-line ECR Ion Source ARTEMIS-B

Get Citation
G.Machicoane, M.Doleans, G.Humenik, F.Marti, P.Miller,
M.Steiner, J.Stetson, X.Wu and P.Zavodszky. R&D Effort at NSCL with the Off-line ECR Ion Source ARTEMIS-B[J]. Chinese Physics C, 2007, 31(S1): 187-191.
G.Machicoane, M.Doleans, G.Humenik, F.Marti, P.Miller,
M.Steiner, J.Stetson, X.Wu and P.Zavodszky. R&D Effort at NSCL with the Off-line ECR Ion Source ARTEMIS-B[J]. Chinese Physics C, 2007, 31(S1): 187-191. shu
Milestone
Received: 2007-05-30
Revised: 1900-01-01
Article Metric

Article Views(2795)
PDF Downloads(657)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

R&D Effort at NSCL with the Off-line ECR Ion Source ARTEMIS-B

    Corresponding author: G.Machicoane,
  • National Superconducting Cyclotron Laboratory, Michigan State University, East Lansing, MI 48824, USA

Abstract: This paper reviews recent experimental work done with the off line source ARTEMIS-B at the NSCL. This source was built during the year 2005 and provides opportunities for off line development that can benefit the Coupled Cyclotron Facility (CCF) operation while minimizing the time taken away from the nuclear experimental program. The Artemis-B setup includes many beam diagnostics and a detailed description of the emittance scanner (Allison) and emittance measurement method is presented. A first beam dynamics study indicates that the analysis magnet has strong field aberrations and that the beam size in the dipole must be small in order to avoid significant beam brightness degradation. A second study compares beam brightness for different focusing systems between the ECR ion source and the analyzing magnet. Two electrostatic devices: a quadrupole triplet and a double quadrupole doublet have been tested successively and compared to a magnetic focusing solenoid. The experimental results tend to indicate a better beam brightness at smaller emittance for the electrostatic devices, although emittances measured for each focusing element were for a large part dependant on the tuning procedure developed to minimize the effects of the analyzing magnet.

    HTML

Reference (1)

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return