×
近期发现有不法分子冒充我刊与作者联系,借此进行欺诈等不法行为,请广大作者加以鉴别,如遇诈骗行为,请第一时间与我刊编辑部联系确认(《中国物理C》(英文)编辑部电话:010-88235947,010-88236950),并作报警处理。
本刊再次郑重声明:
(1)本刊官方网址为cpc.ihep.ac.cn和https://iopscience.iop.org/journal/1674-1137
(2)本刊采编系统作者中心是投稿的唯一路径,该系统为ScholarOne远程稿件采编系统,仅在本刊投稿网网址(https://mc03.manuscriptcentral.com/cpc)设有登录入口。本刊不接受其他方式的投稿,如打印稿投稿、E-mail信箱投稿等,若以此种方式接收投稿均为假冒。
(3)所有投稿均需经过严格的同行评议、编辑加工后方可发表,本刊不存在所谓的“编辑部内部征稿”。如果有人以“编辑部内部人员”名义帮助作者发稿,并收取发表费用,均为假冒。
                  
《中国物理C》(英文)编辑部
2024年10月30日

High Charge State ECR Ion Source-LECR3

Get Citation
ZHANG Zi-Min, ZHAO Hong-Wei, ZHANG Xue-Zhen, GUO Xiao-Hong, LI Xi-Xia, LI Jin-Yu, FENG Yu-Cheng, WANG Hui, MA Bao-Hua, GAO Ji-Yuan, CAO Yun, SUN Liang-Ting and MA Lei. High Charge State ECR Ion Source-LECR3[J]. Chinese Physics C, 2003, 27(10): 914-918.
ZHANG Zi-Min, ZHAO Hong-Wei, ZHANG Xue-Zhen, GUO Xiao-Hong, LI Xi-Xia, LI Jin-Yu, FENG Yu-Cheng, WANG Hui, MA Bao-Hua, GAO Ji-Yuan, CAO Yun, SUN Liang-Ting and MA Lei. High Charge State ECR Ion Source-LECR3[J]. Chinese Physics C, 2003, 27(10): 914-918. shu
Milestone
Received: 2002-12-13
Revised: 1900-01-01
Article Metric

Article Views(1259)
PDF Downloads(668)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

High Charge State ECR Ion Source-LECR3

    Corresponding author: ZHANG Zi-Min,
  • Institute of Modern Physics,CAS,Lanzhou 730000,China

Abstract: A new Electron Cyclotron Resonance (ECR) ion source, which was named LECR3 (Lanzhou Electron Cyclotron Resonance ion source no. 3) and expected to provide highly charged ion beams for atomic physics research, has been constructed and under commissioning. The design of this ion source is based on the IMP 14.5GHz ECR ion source, which was named LECR2 (Lanzhou Electron Cyclotron Resonance ion source no. 2) . In the new source it was desired with double RF heating by inserting waveguide directly and aluminum chamber. Furthermore, the volume of the plasma chamber is larger than that of LECR2 so as to increase the RF power and increase beam intensity for highly charged ions. But the hexapole field on the chamber wall is kept the same value in order to compare with the performance of LECR2 ion source. The results of this ion source are obviously better than LECR2. We obtained 780 euA of 06+, 235euA of O7+ and 240euA of Ar11+ at 1100 watts of 14.5GHz RF power singly. Furthermore, in order to transmit the ion beams efficiently a new beam focusing and analyzing system was designed and constructed at the same time.

    HTML

Reference (1)

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return