[1] |
BAI Zheng-He
, WANG Lin
, JIA Qi-Ka
, LI Wei-Min
. Lattice study for the HLS-Ⅱ storage ring. Chinese Physics C,
2013, 37(4): 047004.
doi: 10.1088/1674-1137/37/4/047004
|
[2] |
ZHANG Lei
, MA Hui-Zhou
, YUE Jun-Hui
, LEI Ge
, CAO Jian-She
, MA Li
. Design of BEPCⅡ bunch current monitor system. Chinese Physics C,
2008, 32(3): 218-221.
doi: 10.1088/1674-1137/32/3/012
|
[3] |
XU Wei
, LI Jing-Yi
, HUANG Sen-Lin
. Conditioning of BPM pickup signals for operations of the Duke storage ring with a wide range of single-bunch current. Chinese Physics C,
2014, 38(10): 107003.
doi: 10.1088/1674-1137/38/10/107003
|
[4] |
Chao-Cai Cheng
, Bao-Gen Sun
, Yong-Liang Yang
, Ze-Ran Zhou
, Ping Lu
, Fang-Fang Wu
, Ji-Gang Wang
, Kai Tang
, Qing Luo
, Hao Li
, Jia-Jun Zheng
, Qing-Ming Duan
. Beam size and position measurement based on logarithm processing algorithm in HLS Ⅱ. Chinese Physics C,
2016, 40(4): 047004.
doi: 10.1088/1674-1137/40/4/047004
|
[5] |
Jia-Jun Zheng
, Yong-Liang Yang
, Bao-Gen Sun
, Fang-Fang Wu
, Chao-Cai Cheng
, Kai Tang
, Jun-Hao Wei
. Central RF frequency measurement of the HLS-Ⅱ storage ring. Chinese Physics C,
2016, 40(4): 047005.
doi: 10.1088/1674-1137/40/4/047005
|
[6] |
WU Cong-Feng
, FAN Hao
, WANG Lin
, LIU Guang-Chao
, FENG Guang-Yao
, LI Wei-Min
. Preliminary study of the higher-harmoni ccavity for HLS-Ⅱ. Chinese Physics C,
2012, 36(9): 891-894.
doi: 10.1088/1674-1137/36/9/017
|
[7] |
Han Yi
, Li-Ming Lü
, Zhao Zhang
, Wen-Jing Cheng
, Wei Ji
, Yan Huang
, Yan Zhang
, Hong-Jie Li
, Yin-Ping Cui
, Ming Lin
, Yi-Jie Wang
, Li-Min Duan
, Rong-Jiang Hu
, Zhi-Gang Xiao
. A Flash-ADC data acquisition system developed for a drift chamber array and a digital filter algorithm for signal processing. Chinese Physics C,
2016, 40(11): 116102.
doi: 10.1088/1674-1137/40/11/116102
|
[8] |
ZANG Yong-Dong
, WU Jun-Xia
, ZHAO Tie-Cheng
, ZHANG Sheng-Hu
, MAO Rui-Shi
, XU Hu-Shan
, SUN Zhi-Yu
, MA Xin-Wen
, TU Xiao-Lin
, XIAO Guo-Qing
. Simulation and measurement of the resonant Schottky pickup. Chinese Physics C,
2011, 35(12): 1124-1129.
doi: 10.1088/1674-1137/35/12/008
|
[9] |
XU Wei
, LI Jing-Yi
, HE Duo-Hui
. A betatron tune measurement system based on bunch-by-bunch transverse feedback at the Duke storage ring. Chinese Physics C,
2013, 37(7): 077006.
doi: 10.1088/1674-1137/37/7/077006
|
[10] |
BAI Zheng-He
, WANG Lin
, JIA Qi-Ka
, LI Wei-Min
. Lattice optimization for the HLS-Ⅱ storage ring. Chinese Physics C,
2013, 37(1): 017001.
doi: 10.1088/1674-1137/37/1/017001
|
[11] |
Kai Tang
, Bao-Gen Sun
, Yong-Liang Yang
, Ping Lu
, Lei-Lei Tang
, Fang-Fang Wu
, Chao-Cai Cheng
, Jia-Jun Zheng
, Hao Li
. Transverse beam size measurement system using visible synchrotron radiation at HLS Ⅱ. Chinese Physics C,
2016, 40(9): 097002.
doi: 10.1088/1674-1137/40/9/097002
|
[12] |
FAN Hao
, WU Cong-Feng
, LIU Guang-Chao
. Calculations of operating schemes for a passive harmonic cavity in HLS-Ⅱ. Chinese Physics C,
2012, 36(9): 895-899.
doi: 10.1088/1674-1137/36/9/018
|
[13] |
XU Wei
, HE Duo-Hui
. Design and optimization of a longitudinal feedback kicker cavity for the HLS-Ⅱ storage ring. Chinese Physics C,
2013, 37(3): 037003.
doi: 10.1088/1674-1137/37/3/037003
|
[14] |
WU Dai
, YANG Ren-Jun
, BAI Wei
, LI Peng
, LI Ming
, YANG Xing-Fan
. Design study of an improved laser wire system for electron beam measurement. Chinese Physics C,
2013, 37(10): 108101.
doi: 10.1088/1674-1137/37/10/108101
|
[15] |
YE Jin
, YUE Qian
, LI Yuan-Jing
, CHENG Jian-Ping
, LI Jin
, WANG Yi
. Effect of the integrated time of the induced current signal on the position resolution of the RPC detector. Chinese Physics C,
2009, 33(8): 673-676.
doi: 10.1088/1674-1137/33/8/014
|
[16] |
ZHU Xiong-Wei
, GAO Jie
. Study on ILC bunch compressor. Chinese Physics C,
2008, 32(11): 928-930.
doi: 10.1088/1674-1137/32/11/016
|
[17] |
CHEN Yu-Kai
, LI Yu-Xiong
, LI Wei-Min
, HE Li-Juan
. Theoretical analysis of BLM system for HLS Ⅱ. Chinese Physics C,
2015, 39(1): 017003.
doi: 10.1088/1674-1137/39/1/017003
|
[18] |
FAN Hao
, WU Cong-Feng
, WANG Lin
. Tracking simulations for the HLS-Ⅱ with a passive harmonic cavity in the symmetricand asymmetric fill patterns. Chinese Physics C,
2012, 36(11): 1111-1115.
doi: 10.1088/1674-1137/36/11/013
|
[19] |
LI Jing-Yi
, LIU Gong-Fa
, XU Wei
, LI Wei-Min
, LI Yong-Jun
. A possible approach to reduce the emittance of HLS-Ⅱ storage ring using a Robinson wiggler. Chinese Physics C,
2013, 37(10): 107006.
doi: 10.1088/1674-1137/37/10/107006
|
[20] |
Li Jin
, Mao Zepu
. Measurement of the Bunch Length of Beijing Electron Positron Collider. Chinese Physics C,
1991, 15(S3): 219-225. |