Setup of a photomultiplier tube test bench for LHAASO-KM2A

Get Citation
Xu Wang, Zhong-Quan Zhang, Ye Tian, Yan-Yan Du, Xiao Zhao, Fu-Wang Shen, Chang-Yu Li, Yan-Sheng Sun and Cun-Feng Feng. Setup of a photomultiplier tube test bench for LHAASO-KM2A[J]. Chinese Physics C, 2016, 40(8): 086003. doi: 10.1088/1674-1137/40/8/086003
Xu Wang, Zhong-Quan Zhang, Ye Tian, Yan-Yan Du, Xiao Zhao, Fu-Wang Shen, Chang-Yu Li, Yan-Sheng Sun and Cun-Feng Feng. Setup of a photomultiplier tube test bench for LHAASO-KM2A[J]. Chinese Physics C, 2016, 40(8): 086003.  doi: 10.1088/1674-1137/40/8/086003 shu
Milestone
Received: 2015-12-11
Revised: 2016-03-05
Fund

    Supported by NSFC (11075096) SDNFS (ZR2011AM007), China

Article Metric

Article Views(1850)
PDF Downloads(267)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Setup of a photomultiplier tube test bench for LHAASO-KM2A

    Corresponding author: Cun-Feng Feng,
  • 1. School of Physics and Key Laboratory of Particle Physics and Particle Irradiation (MOE), Shandong University, Jinan 250100, China
Fund Project:  Supported by NSFC (11075096) SDNFS (ZR2011AM007), China

Abstract: To fulfill the requirements for testing the photomultiplier tubes (PMTs) of the electromagnetic detector at the Large High Altitude Air Shower Observatory (LHAASO), a multi-functional PMT test bench with a two-dimensional scanning system has been developed. With this 2D scanning system, 16 PMTs can be scanned simultaneously for characteristics tests, including uniformity, cathode transit time difference, single photo-electron spectrum, gain vs. high voltage, linear behavior and dark noise. The programmable hardware and intelligent software of the test bench make it convenient to use and provide reliable results. The test methods are described in detail and primary results are presented.

    HTML

Reference (4)

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return