Calculation of Depth-Dose Distribution of Intermediate Energy Heavy-Ion Beam

  • A complex straggling algorithm is presented to calculate depth dose distribution of intermediate energy heavy-ion beam. Relative dose Bragg curves of carbon and oxygen ion beams with intermediate energies were computed according to the algorithm above. Comparisons between the relative doses predicted and measured were taken up. The Bragg curves predicted by the complex straggling algorithm show a good agreement with the experimental data. So the reasonableness of this algorithm and its reliability for calculating depth doses were verified. Hence the principle and method to deduce the depth dose distribution of therapeutic beam was integrated after this algorithm was developed.
  • 加载中
  • [1] Sihver L, Tsao C H, Silberberg R et al. Adv. Space Res.,1995, 17(2):105-108[2] Affix F H. Topics in Radiation Dosimetry, Radiation Dosimetry Supplarsent 1. New York and London, Academic press. 1972 , 404-409[3] Kox S, Gratnp A. Perrin C et al. Phys. Rev.,1987, C35;1678-1691[4] LI Qiang, WEI ZengQuan, LI Wen,lian et al. High Energy Phys. and Nucl. Phys. ( in Chinese),1998,22(7):646-650 (李强.卫增泉.李文建等.高能物理与核物理.1998.22(7)".64b-650)
  • 加载中

Get Citation
LI Qiang, WEI ZengQuan and LI WenJian. Calculation of Depth-Dose Distribution of Intermediate Energy Heavy-Ion Beam[J]. Chinese Physics C, 2000, 24(5): 414-417.
LI Qiang, WEI ZengQuan and LI WenJian. Calculation of Depth-Dose Distribution of Intermediate Energy Heavy-Ion Beam[J]. Chinese Physics C, 2000, 24(5): 414-417. shu
Milestone
Received: 1999-04-06
Revised: 1900-01-01
Article Metric

Article Views(2517)
PDF Downloads(590)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Calculation of Depth-Dose Distribution of Intermediate Energy Heavy-Ion Beam

    Corresponding author: LI Qiang,
  • Institute of Modern Physics, The Chinese Academy of Sciences, Lanzhou 730000, China

Abstract: A complex straggling algorithm is presented to calculate depth dose distribution of intermediate energy heavy-ion beam. Relative dose Bragg curves of carbon and oxygen ion beams with intermediate energies were computed according to the algorithm above. Comparisons between the relative doses predicted and measured were taken up. The Bragg curves predicted by the complex straggling algorithm show a good agreement with the experimental data. So the reasonableness of this algorithm and its reliability for calculating depth doses were verified. Hence the principle and method to deduce the depth dose distribution of therapeutic beam was integrated after this algorithm was developed.

    HTML

Reference (1)

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return